| Product name | Reverse Osmosis Sparkling Water Dispenser | |
|---|---|---|
| Product model | W60 | |
| Rated voltage | 110~ | 220-240V~ |
| Rated frequency | 60Hz | 50/60Hz |
| Rated power | 1600W | 2300W |
| Rated heating power | 1500W | 2200W |
| Rated cooling power | 110W | 120W |
| Water heating capacity | 16L/h(≥90°C) | 18L/h(≥90°C) |
| Water cooling capacity | 3L/h(≤10°C) | |
| Working pressure | 0.4~0.6MPa | |
| Applicable water source | City water | |
| Applicable water temperature | 5-38°C | |
| Water tank capacity | 5L | |
| Net weight | 20 kg | |
| Dimensions | 467x220x430mm | |
For compression equipment using combustible refrigerants, the manual should include information on how to install the equipment:
Direction 1: Forward
◇ When in designing a refrigeration system, full consideration should be given to the return oil of the system.
◇ Damaged compressors are not allowed to be used.
◇ After the compressor is installed on the box, it must always be kept vertical during transportation. Direction One as shown in the figure below. Priority should be given to “direction one” during loading and unloading, and in case of special circumstances, it must be turned to the side. When reversing, it is recommended to use “direction two” first, followed by “direction three”. Any adverse conditions caused by handling in other directions should not be related to the compressor itself, and our company will not assume any related responsibility.
Installation instructions
System vacuum degree (compressor): 0.025Mpa
Non-condensable gases are limited to: 1%
Maximum connector opening time: 10 minutes
The compressor cannot withstand high voltage or start or operate under vacuum conditions, and cannot be used for system vacuum pumping.
The inclination between the compressor and the horizontal state during operation shall not exceed 5°.
Using non specified types of refrigeration oil: prohibited
Compressor return liquid: not allowed
The inventory period of the compressor after leaving the factory should not exceed 6 months.
If it exceeds 6 months, please check if the dry air in the compressor is sufficient and supplement it if necessary.
Insert the plug, switch on the power, the buzzer will sound “Ding”, and the display panel will light up after initialization is completed. The machine will enter sleeping mode. The display panel will light off if there is no operation in 5 minutes. Touch the main screen to light up the display panel.
Pipeline mode switching: The default setting is with the original water tank mode. If you need to switch to pipeline mode, press this button to start; the machine will remember this setting from now on. Under pipeline mode, it must make sure to plug in the input water pipe and wastewater pipe. (Please refer to the water pipe installation drawing for operation.) Under pipeline mode, turn off the faucet of tap water before starting to press the drain button. (Notes: Left and right side water outlets under the display panel will drain together.)
If you need to switch back to the original water tank mode in the pipeline mode, you need to turn off the pipeline mode in the system settings on the screen, pull out the water inlet line and wastewater line on the back at the same time, and insert the plug back into the water inlet hole and wastewater hole, respectively, before the original water tank mode can be used normally.
| Icon | Function description |
|---|---|
![]() | Back to Home button |
| water shortage of pure water tank | The red light indicates that the pure tank is short of water |
| water shortage of raw water tank | The red light indicates a shortage of water in the original tank |
| UV | Indicates that the UV sterilization function is enabled. |
| CO₂ | The white light means there is enough carbon dioxide gas, and the red light means there is no carbon dioxide gas or no gas cylinder is installed. |
| H₂CO₃ | The red light indicates that carbon dioxide gas is infused into sparkling water in pure water. Please wait 1–2 minutes. Use the machine's default ice water (≤10°C) to make sparkling water. |
| The filter life reminder light is divided into white, yellow, and red lights. When 20% < filter life ≤ 100%, the filter indicator will show white. When 0 < filter life ≤ 20%, the filter indicator light shows yellow. When the filter life is equal to 0, the filter indicator shows red. |
Attention:
♦ The cooling setting must be enabled for the bubble water function. If the cooling function is not enabled, the bubble water function cannot be used.
♦ Bubble water contains carbon dioxide, the outlet pressure is large, the discharge flow is not very accurate, and there is a small amount of jet when the outlet is produced. This is a feature of the function; this is a normal phenomenon.
♦ When the bubble water does not come out, please check whether the carbon dioxide cylinder has been used up in advance, such as after the gas is used up. Replace the new CO₂ cylinder assembly.
♦ The bubble water function product will have slight vibration and noise when it comes out of the water, which is a normal phenomenon, because the pressure of the bubble tank is large, and the pump needs to pump the net water into the bubble tank.
Warm reminder :
♦ Each person’s taste and concentration requirements for sparkling water are different, and the concentration needs to be adjusted according to personal tastes and preferences. If you find the taste of sparkling water too strong, you can try adding some fruit or juice to the sparkling water to increase the texture and taste. For example, lemons, strawberries, blueberries, etc., are good choices.
♦ If you feel that the taste of sparkling water is too strong, you can try to reduce the pressure of the sparkling water or add more pure water to dilute it. In addition, you can also add some moderate sweetener or sugar to balance the taste. For example, honey, sugar, maple syrup, etc.
♦ In the first use of bubble water, carbon dioxide gas needs to be thoroughly dissolved into the cold tank. Inside, all the water needs to wait for ten minutes, which is the characteristic of bubble water.
Operate with “self-cleaning” when first used or after replacing the filter. Press “System setting” in the main screen, and press the function “Self cleaning” into
the automatic cleaning mode.
1. Press “Drain” mode to clean out all the water in the tank; under drain mode, two outlets will flow out water together; please place water containers under the outlets.
2. After finishing the drains, press “Start” into “Self-cleaning” mode. After finishing the self-cleaning, the two outlets will stop flowing out water.
3. After finishing self-cleaning mode, please fill the water tank. Notes: If you need self-cleaning, please repeat STEP 2)
4. After finishing the above steps, please place the CO₂ tank in the designated position to enter normal use status.
Notes: The can not be placed in the designated position before cleaning. It must be placed in the machine after finishing cleaning.
Notes:
1. The buzzer will sound “Ding” when the operation is valid for pressing the button each time.
2. The machine will clean for 5 seconds when starting operation or each time the water tank is filled. The water icon will light up in the display panel.
Notes:
1. The buzzer will sound “Ding” when the operation is valid for pressing the button each time.
2. The machine will clean for 5 seconds when starting operation or each time the water tank is filled. The water icon will light up in the display panel.
Step 1: Turn off the power supply, open the gas tank cover, hold the notch of the cover by your finger and pull it up to open the tank cover.
Step 2: When open the cover, hold the bottom of the bottle to pull outward, rotate the bottle by counterclockwise.
Step 3: Remove the sealing of new gas bottle, place the spout to the machine’s connector of relief valve. The connector can be pulled up to align with the bottle’s spout, rotating the bottle with clockwise and fix. Close the tank cover.
Step 4: After replacement of gas bottle, white writing of CO₂ will be shown in display panel again, means that the gas bottle has been fixed.
Step 1: Turn off the power, open the water tank cover, push backward the top lid of the machine.
Step 2: Rotate the filter counterclockwise and take it out upward.
Step 3: Assemble the new filter and rotate it by clockwise to tighten
Step 4: Press button of machine status into the replacement of filter and press reset. After finished filter replacement, it suggests operating with self-cleaning function to clean the new filter.
Note: Original filter element must be used for replacement to ensure the safety of drinking water. For any abnormal situation during the replacement of filter element, please contact the customer service center in time
To ensure the best experience, follow these steps to empty the device before first use:
1. Preparations
Place the machine on a smooth, ventilated table.
Fill the tank with room temperature drinking water to the MAX line (do not use hot water or sugary liquids)
2. Start the drain procedure
After turning on the machine, click the system Settings-self-cleaning function at the bottom of the screen, and press the [drainage] button briefly. The machine will automatically discharge residual gas and water.
3. Confirmation is completed
When the cleaning icon in the middle of the screen stops jumping, it means that the emptying is complete.
Matters need attention
A brief “squeak” will occur when emptying, which is normal.
| Filter element for short | Type of filter element | Function | Recommended replacement period |
| RO | 4 in 1 RO Reverse osmosis composite filter element | Removal of impurities such as silt, rust, sand, suspended solid and blood worm; Removal of residual chlorine, germ, heavy metal and absorption of disagreeable tastes and odors; Prevent the growth of germ and improve the tastes. | 24 months |
W60 Installation
How to Use the W60
Something isn’t Clear?
Feel free to contact me, and I will be more than happy to answer all of your questions.
Enter you email below, so we can send you this valuable report.